Option 66 - Pre-Checks - Honeywell Galaxy Dimension Series Installer Manual

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual
Option 66 – Pre-checks
The Pre-Check option provides added system security by alerting the user to zones that may not be operating
correctly.
NOTE: Pre-check does not operate when the system is in the engineer mode.
Testing Zones
The Entry/Exit Horns beep once when each zone is tested. As each zone is successfully tested, the keypad
indicates the number that remain to be tested. When the last zone is successfully tested the Entry/Exit Horn
sounds twice and the keypad displays 0 CHECK ZONES; press the ent key to resume the system routine.
1 = Mode
The Mode determines the pre-check level that the selected zones are subjected to before the system can set.
The Mode is selected from one of the following:
1. Disabled (default): the pre-check option is disabled; even if zones are selected, they are not checked.
2. Warning: when the setting routine is started the user is informed of the number of selected pre-check
zones that have not been activated since the system was unset; press the A or B keys to view the zones.
Press the ent key to continue the setting routine. The zone that have not been activated do not have to be
tested.
3. Autocheck: when the setting routine is started the user is informed of the number of selected pre-check
zones that have not been activated since the system was unset and a warning is sounded; press the A or B
keys to view the zones. These zones must be tested before setting can be resumed.
4. Forced Check: when the setting routine is started the keypad indicates the number of pre-check zones
that are on the system; to view the pre-check zone addresses press the A or B keys. All of the pre-
selected zones must be tested before setting can take place.
2 = Select Zones
On selecting 2 = Select Zones, the address and function of the first zone on the system is displayed. Move to
the required zone by pressing the A or B keys or by entering the zone address. To toggle the status of the pre-
check attribute of the zone press the # key; the keypad indicates that the zone is included in the pre-check by
displaying PRE-CHECK ZONE. Select other zones to be pre-checked in the same way. Once all of the
zones have been selected, press the esc key.
16 CHECK ZONES
A=VIEW
0 CHECK ZONES
ENT=VIEW
6-175
66 - Pre-Check

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents