Mounting - Honeywell TrueZONE HZ432K/U Installation Manual

Table of Contents

Advertisement

Installation Guide

MOUNTING

Mount the HZ432 TrueZONE panel near the HVAC
equipment; locate it on a wall, stud, roof truss, or cold-
1
air return.
NOTE: The HZ432 TrueZONE panel can be mounted in
any orientation; level it for appearance only.
Separate the zone panel cover from the base, and use the base as a template to drill mounting holes.
2
Attach the base to the wall, stud, roof truss, or duct with appropriate screws (not included).
Fig. 3
69-2198—03
Use two screws for attaching to a stud or roof truss, or
four screws for duct or drywall/plaster installations.
M24807
SPRD BYPASS
DAMPER
DATS
(ALTERNATE
LOCATION)
TrueZONE PANEL
MOUNTED ON
RETURN DUCT
DATS
(AT LEAST 3 FT
FROM PLENUM)
2
ZONE DAMPERS
SUPPLY
DUCT
MOUNTED ON WALL
FURNACE OR
AIR CONDITIONER
Fig. 2
ZD SERIES
TrueZONE PANEL
M24738

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Truezone hz432Truezone hz432/u