Nilfisk-ALTO FLOORTEC R 870 Service Manual page 52

Table of Contents

Advertisement

Service Manual – Floortec R 870
Electric Fan Disassembly/Assembly (Continues)
6
At the workbench, disconnect the connector (D) from the electrical cable (E), by disengaging its pins.
7
Unscrew the bulkhead cap (F)
8
Remove the external screws (G) and remove the electric fan assembly (H) with its wiring harness (E)
9
If necessary, remove the electric vacuum fan (I) from the assembly (H) as shown below.
• Unscrew the three nuts (J) and remove the screws (K)
• Remove the plate (L) and the electric fan (I)
Assembly
10 Assemble the components in the reverse order of disassembly
J
I
K
L
G
J
J
Dust Control System
G
D
E
F
H
J
H
P200109