Service Manual – Floortec R 870
Main Broom Motor Carbon Brush Check/Replacement
Disassembly
1
Remove the main broom motor (see the procedure in the previous paragraph)
2
At the workbench, remove the nuts (A) and the guard (B) of the main broom motor (C).
3
If necessary, clean the external side of the motor (C) in the area of the protection band (D).
4
Disengage the cam lever (E) and remove the protection band (D)
5
Remove the fastening screws (F) of the electrical connections of the four carbon brushes (G)
6
Remove the four carbon brushes (G) from their housings, by disengaging them from the retaining
springs (H)
7
Check the carbon brushes (G) for wear. The carbon brushes are worn when:
• The contact with the motor armature is insufficient
• The contact surface is not integral
• The stroke is less than 0 12 in (3 mm)
• The spring is broken
In this cases, replace all motor carbon brushes.
Assembly
8
Assemble the components in the reverse order of disassembly