Service Manual – Floortec R 870
d BATTERY PROTECTION: Battery charge status is shown by the 3 LEDs depending on the type of
battery (WET/GEL) according to the following diagram:
Green LED on (fixed)
1
Yellow LED on (fixed)
2
Red LED flashing
3
When the red LED starts flashing, broom function is automatically deactivated.
e BATTERY TYPE DISPLAY (WET/GEL): Each time the machine is turned on with the ignition
key, the 3 battery charge LED indicators show the battery type as follows:
Flashing pattern
Battery Type
4 flashes of the RED warning light
WET
4 flashes of the GREEN warning light
GEL
f PROCEDURE FOR BATTERY SETTING (WET/GEL): Hold the push-button (B) down while
you turn the key on and hold it for 5 sec The 3 LEDs will then show again the current setting with
the continuous flashing of the corresponding LED (see the previous step), while further pressing
the push-button (B) will change the current setting The last setting will be stored when (B) is not
pressed for more than 5 sec
g TIMED FUNCTION ACTIVATION: BROOM, VACUUM and FILTER SHAKER are turned on and
off by pressing the relevant controls and according to the conditions of the relevant sensors as shown
in their respective chapters
OTHER INDICATIONS WITH DEDICATED WARNING LIGHTS: fuel reserve warning light
(D), vacuum system warning light (E), dust guard system warning light (F), hopper lifting warning
light (G), main broom overpressure warning light (C), drive system diagnostic warning light (I).
E
D
B
WET
V>22.0
22.0>V>20.4
V>20.4
F
Control System
GEL
V>22.2
22.2>V>21.6
V>21.6
G
C
I