Service Manual – Floortec R 870
Engine System - LPG
128
Solenoid Valve Removal/Installation (Continues)
9
Disconnect the electrical connections (D) and (F)
10 Remove the fastening screws (G) of the pressure regulator assembly with valves (H)
11 Remove the pressure regulator assembly with valves (H)
12 At the workbench, remove the "T" fitting (I) from the fitting (L).
13 Remove the solenoid valve (J) from the fitting (K).
14 Unscrew the fitting (L) from the solenoid valve (J).
15 Retrieve the solenoid valve (J)
Assembly
16 Assemble the components in the reverse order of disassembly
17 Perform the LPG System Leakage Check (see the procedure in LPG System Leakage Check paragraph)
F
D
K
J
I
L
H
G
P200150