Service Manual – Floortec R 870
Filter Shaker Motor Disassembly/Assembly (Continues)
6
Release the fastening clamp and disconnect the filter shaker connector (K).
7
Loosen the knobs (D) and (E), then remove the filter shaker assembly (F), by sliding it forward,
disengaging it by the knobs (D) and then by the knobs (E)
8
At the workbench, remove the nuts (G) and remove the fastening clamps (H) of the filter shaker motor
(I) Retrieve the washers (J)
9
Remove the filter shaker motor (H), by disengaging the dowel (L) from its seat.
Assembly
10 Assemble the components in the reverse order of disassembly