Nikon Eclipse Ni-E Instruction Manual page 27

Upright motorized microscope
Hide thumbs Also See for Eclipse Ni-E:
Table of Contents

Advertisement

Setting
DS-L3
Buttons displayed on the [MICROSCOPE
CONTROL] screen
DS-L3
Buttons displayed on the [CAM-MIC
CONTROL] screen
DS-L3
Hiding the [SLEEP] button on the
[MICROSCOPE CONTROL] screen
Interlocked operation of the objective
Interlocked operation when switching zoom
magnification
Interlocking operations with the switching of
the optical path
Automatic operation interlocked with
capture button operation
Retracting amount of the elevating section
Rotation stop of the nosepiece depending
on the position of the elevating section
Reverse rotation stop of the nosepiece
Toggle rotation of the nosepiece
[MODE] (Registration of motorized unit for MODE)
Registering a motorized unit with mode (8
modes)
Setting the display pattern of the Ni-E front
display panel
Enabling/disabling the operation of the
elevating section
Setting the XYZ position software limit
Buzzer that sounds when you press
operation buttons
[MAINTENANCE]
Movement speed of the epi-fluorescence
cube turret
Resetting data
Display of the program version
Chapter 2
Microscopy Operations
Default setting
Configured
(See DS-L3 Chapter 2 "3.1
[MICROSCOPE
CONTROL] Screen (Ni-E)".)
Configured
(See DS-L3 Chapter 2 "3.2
[CAM-MIC CONTROL]
Screen (Ni-E)".)
Hidden
[MOVEMENT]
OFF
OFF
OFF
OFF
Software limit position
No rotation stop
No rotation stop
Toggle operation OFF
Not registered
[UTILITY]
Pattern 1
(See Chapter 3 "1 Display
Panel Details".)
Enabled
Z-axis: 2000.000 μm
X-axis max. value:
34000.000 μm
X-axis min. value:
-34000.000 μm
Y-axis max. value:
27000.000 μm
Y-axis min. value:
-27000.000 μm
When pressing the button
of the Ni-E main body:
Buzzer sounds
When pressing the button
of the ergo controller:
No buzzer sound
Set to "High Speed"
...
...
Where to see in this manual (DS-L3 for details)
→DS-L3 Chapter 6 "4.1.1 Selecting the Buttons to
be Displayed"
→DS-L3 Chapter 6 "4.1.1 Selecting the Buttons to
be Displayed"
→DS-L3 Chapter 6 "4.1.2 Showing/Hiding the
[SLEEP] Button"
→Chapter 3 23.1-(4)
→DS-L3 Chapter 6
"5.1.1 Configuring the Interlocked Operation with
Switching of Objectives"
"5.1.2 Changing the Initial Value of the
[INTELLIGENT]"
"5.1.3 Automatically Switching the Movement
Speed of the Microscope's Elevating Section
and Motorized Stage"
"5.1.4 Configuring the Parfocal Correction
Function (Auto Link Focus)"
→DS-L3 Chapter 6 "5.1.5 Configuring the
Interlocked Operation with Switching of Zoom
Magnification"
→DS-L3 Chapter 6 "5.1.6 Configuring the
Interlocked Operation with Switching of Optical
Path"
→DS-L3 Chapter 6 "5.1.7 Configuring the
Interlocked Operation with Capture Command
Sending or Trigger Signal Output"
→DS-L3 Chapter 6 "5.2 Setting the Retracting
Amount of the Elevating Section"
→DS-L3 Chapter 6 "5.3 Disabling the Rotation of
the Motorized Nosepiece Depending on the
Position of the Elevating Section"
→DS-L3 Chapter 6 "5.4 Disabling the Reverse
Rotation of the Nosepiece"
→DS-L3 Chapter 6 "5.5 Configuring the Toggle
Function (Alternating between Two Objectives)"
→Chapter 3 23.1-(5)
→DS-L3 Chapter 5 "2.1 Registering/Changing
Target Motorized Devices"
→Chapter 3 23.1-(6)
→DS-L3 Chapter 6 "6.1 Setting the Display of the
Ni-E Front Display Panel"
→DS-L3 Chapter 6 "6.2 Enabling/Disabling the
Operation of the Elevating Section"
→DS-L3 Chapter 6 "6.4 Setting the Software
Limits"
→DS-L3 Chapter 6 "6.3 Turning ON/OFF the
Buzzer"
→Chapter 3 23.1-(7)
→DS-L3 Chapter 6 "6.5 Setting the Driving Speed
of the Epi-Fluorescence Cube Turret"
→DS-L3 Chapter 6 "6.6 Restoring the Factory
Default Settings"
→DS-L3 Chapter 6 "6.7 Displaying the Program
Version"
13