Amano Time Guardian Series Installation And User Manual page 389

Security access keypads
Table of Contents

Advertisement

4. In the TZ (Time Zone) Offset fields, select the time zone difference (if applicable) between
the physical location of your PC and the terminals in Hours and Minutes.
5. The Output Path field is not used and grayed out.
6. The "Secondary Output File" box is not used and grayed out.
7. The DLS (Daylight Savings Time) Settings are not used and grayed out.
8. Click on the Connection tab.
9. In the Connection field, Ethernet is fixed for the type of connection you are using to
communicate with the terminal(s). The terminals communicate to the Host PC via Ethernet
connection. You must enter the IP Address and Port (default port = 10,005). [Obtain the
correct IP address from your network administrator, or alternatively, please consult the
appropriate terminal manual to perform terminal diagnostics, hardware configuration, and
identify the IP address].
10. Click on the Select Terminals
figure). The Ethernet connected terminals in this location should appear in the Terminals list
(see figure). The User Datagram Protocol (UDP) Output of the Nexus Lite must be set to the
IP Address of the NLM client PC. Also, NLM utilizes a UDP Service which runs in the
background on the NLM client. The UDP Service must be running for this communication.
The "Receiving Port Number" on the Nexus Lite must be set to the same as the NLM client
which has a default = 4445. (See Network Module).
– Nexus Lite Module
Time Guardian Series
button to see a list of discovered terminals (see
23-19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents