WELDED PANEL REPLACEMENT -
Center pillar
silencer
protector
<The following service procedures are only applied to
RS-II.>
5. When attaching the center pillar inner, attach the center
pillar silencer protector to the center pillar inner, and seal
the holes of the center pillar silencer protector with butyl
tape.
6. After attaching the center pillar outer, seal the holes and
flanges with bolts and plate tape, fill the foam material
through the holes as shown in the illustration.
Foam material
Type
Two - part
Foam acoustic
panded urethane
material
7. About two hours after filling the foam material, remove
the bolts and plate tape, and solder the sealed holes
until a clip, etc. can be inserted completely.
Center Pillar
Brand Used
ex-
3M ULTRAPRO
Panel foam - Yellow
C-11