Window Malfunction; Power Window Safety Mechanism Check; Power Window Timer Function Check - Mitsubishi Electric Lancer Evolution-VII Workshop Manual

Table of Contents

Advertisement

42-22
Runchannel
BODY -
ADJUSTMENTS AND REPLACEMENT DURING
POWER WINDOW MALFUNCTION
Door
sash
If the window glass does not rise but automatically descends,
adjust and replace the window glass as follows:
1. Remove the door trim and waterproof film. (P.42-27)
2. Remove the window regulator assembly from the door
window glass, and raise and lower the window glass with
Lower sash
your hand and check the operating force.
Remarks Insert a cushion, etc. to prevent damage of
the glass if it accidentally drops.
3. If the door window glass does not rise and descend
smoothly, perform the following check and repair.
D
D
D
NOTE
The lower sash cannot normally be adjusted, but it may
be possible to adjust the sash span slightly within the
range allowed by manufacturing tolerances by pushing
the lower sash outwards while re-installing it.
4. If repair or adjustment is not possible, replace the door
assembly.
POWER WINDOW SAFETY MECHANISM
CHECK
1. Set a wood piece of about 10 mm thick as shown in
the figure, and raise the window glass.
2. Check that the window glass descends by about 150
mm when it catches the wood piece. If it does not, perform
troubleshooting. (Refer to GROUP 54B.)

POWER WINDOW TIMER FUNCTION CHECK

9Close the door and turn the ignition switch in the OFF position,
and then check the power window operates for 30 seconds.
If it does not, perform troubleshooting.(Refer to GROUP 54B.)
Doors
Check the installation condition of the runchannel.
Straighten twist in the door sash.
Check the installation condition of the lower sash
or the center sash.