Communication Programming; Split/Dual Reporting Table - ADEMCO Vista-10SEa Installation And Setup Manual

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

Communication Programming

Introduction
This section provides instructions for programming those fields that affect communications
between the control and the central station.
Programming Procedure
1. With at least one alpha keypad (6139) connected to the system, power up the system. If
necessary, refer to Section 10: FINAL POWER-UP for the power-up procedure. If you
previously connected the AC transformer to the control panel, you need only plug in the
plugpack (to a 230VAC outlet) to power up the system.
2. Enter the Programming mode by keying the following on the alpha keypad: Installer
code (4 1 1 1) + 8 + 0.
Fields 40, 41, 42, 44
Enter up to the number of
digits shown. Do not fill
unused spaces.
Enter 0–9,
# + 11 for " "
# + 12 for "#"
# + 13 for a pause
(2 secs)
Press 40 PABX ACCESS CODE
Enter up to 4 digits if PABX is needed to access an outside
line. If you need to enter fewer than 4 digits, exit by pressing
[ ] and next field number (e.g., 41). To clear entries from
field, press 40 .
Press 41 PRIMARY PHONE NO.
Enter up to 12 digits. If you enter fewer than 12 digits, exit
by pressing [ ] and next field number (e.g., 42). To clear
entries from field, press 41 .
Press 42 SECONDARY PHONE NO.
Enter up to 12 digits. If you enter fewer than 12 digits, exit
by pressing [ ] and next field number (e.g., 43). To clear
entries from field, press 42 .
Press 43 SUBSCRIBER ACCOUNT NO.
Press 45 PHONE SYSTEM SELECT
If central station receiver is not on a satellite-linked line:
0 = Pulse Dial, 1 = Tone Dial.
If central station receiver is on a satellite-linked line:
2 = Pulse Dial, 3 = Tone Dial. (Default is 1.)
Press 46 REPORT FORMAT, PRIMARY/SECONDARY
Determines which format is to be used to report to the central
station.
0 = ADEMCO Contact ID Reporting
1 = ADEMCO Local Audio (Default is 0.)
NOTE: The maximum number of Alarm and Alarm Restore
reports during one armed period is determined by field
92.
Press 47 SPLIT/DUAL REPORTING
Enter 0 to disable (Backup report only). (Default is 0.)

Split/Dual Reporting Table

TO PRIMARY PHONE #
1 =
Alarms, Restore, Cancel
2 =
All except Open/Close, Test
3 =
Alarms, Restore, Cancel
4 =
All except Open/Close, Test
5 =
All reports
Section 13: System Communication
TO SECONDARY PHONE #
Other Reports
Open/Close, Test
All reports
All reports
All reports
13-3