Removing A Zone From The System (5800 System) - ADEMCO Vista-10SEa Installation And Setup Manual

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

VISTA-10SEa Installation and Setup Guide
10 Confirmed
A022– 4064
At any time during this step, you may press the [ ] key on the keypad or the upper left-hand
button of the program tool if you are satisfied with the serial and loop number combination that
has been enrolled, regardless of whether or not the enrolled input has been "confirmed."
If the incorrect transmitter has been enrolled, press the # key on the keypad or the upper right-
hand button of the program tool to delete the serial number and return to the "Learn S/N" prompt.
The keypad will emit a single long beep to verify your pressing of the upper right-hand button.
Then, press "1" (Yes) or press the upper left-hand button of the program tool (a single short beep
will verify the system is ready for enrolling) and re-activate the proper transmitter or transmitter
loop input.
ZN ZT – RC IN: L
10 03 – 00 RF: 1 s
Program Alpha?
0 = NO
Enter Zn Num.
(00 = QUIT )
When you have finished programming all zones (including all serial numbers), test each zone
using the system's TEST mode. Do not use the Transmitter ID Sniffer mode for this, as it will
check only for transmission of one zone on a particular transmitter, and NOT the zones assigned
to each additional loop.
Removing a Zone from the System Temporarily or Permanently (5800 System)
1. Enter the programming mode:
Key Installer Code + 8 + 0 and press [ ][5][6].
6-10
1
13. The summary screen for the zone will appear. Note that
14. If you want to program alpha descriptors now, enter "1"
1 = YES 0
11
the operation of the actual programmed input can be
confirmed. Activate the loop input or button that
corresponds to this zone.
confirm the programming of every transmitter
before proceeding to the next zone.
When the system sees activity on the appropriate input,
it will beep three times and display the confirmation
message.
an "s" indicates that a serial number has, in fact, been
enrolled. The cursor will be flashing above the loop
number. Press [ ] to accept the zone information.
NOTE: If you entered "0" in step 10, you will not get an
indication that the serial number has been
enrolled.
If you want to delete the serial number, enter "0" and
press [ ]. The system will then prompt, "Delete S/N?"
Press the "1" (Yes) key to complete the delete sequence.
This process deletes the serial number only, not the loop
number. The assumption is that the proper loop number
was programmed, but the wrong serial or loop number
was enrolled. To change the loop number, you must go
back through zone programming for that zone and
manually enter the loop number over the existing one.
(Yes).
See
Section
PROGRAMMING for more information.
If not, enter "0" (No).
This will bring you back to the "Enter Zn Num." prompt
for the next zone. When you have programmed all
zones, enter "00" to quit.
If you plan to enroll serial numbers in the sequential
mode, enter "00" to quit, then go to Section 12:
SEQUENTIAL MODE to enroll the serial numbers.
We recommend that you
11:
ALPHA
DESCRIPTOR

Hide quick links:

Advertisement

Table of Contents
loading