02
A EV ZL ZT
STP –
0
00
02 Relay Action
No Response
0
02 Start Event
Not Used
0
02 Start:
Zn List
No List
0
02 Start:
Zn Typ
Not Used
00
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry
31 = End of Exit Time
32 = Start of Entry Time
02 Stop:
Zn List
No List
0
02 Stop:
Zn Typ
Not Used
00
02
A EV ZL ZT
STT 0
0
0
00
This screen displays a summary of the current relay STOP
programming.
Press [ ] to continue.
Enter the desired relay action:
0 = No response
1 = Close for 2 seconds
Press [ ] to continue.
Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a
zone type/system operation is to be used instead of an event,
enter 0.
Press [ ] to continue.
If a zone list will be used to START the relay action, enter the
zone list number (to be programmed in field 81): 1, 2, or 3.
If not, enter 0.
Press [ ] to continue.
If a zone type or system operation will be used to START the
relay action, enter the appropriate two-digit code (see table
that follows on the next page). If not, enter 00.
Press [ ] to continue.
CHOICES FOR ZONE TYPES
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24-Hr Silent
07 = 24-Hr Audible
CHOICES FOR SYSTEM OPERATION
33 = Any Burglary Alarm
34 = Code + # + 7 Key Entry
36 = At Siren Timeout**
38 = Chime
**Or at disarming, whichever occurs earlier.
If a zone list will be used to STOP, or restore, the relay action,
enter the zone list (ZL) number 1, 2, or 3 (to be programmed in
81 mode). If not, enter 0.
Press [ ] to continue.
If a zone type or system operation will be used to STOP the
relay action, enter the appropriate two-digit code (see the "ZT"
choices listed above). If not, enter 00.
Press [ ] to continue.
This screen again displays a summary of the current relay
START programming.
Press [ ] to continue.
Section 7: Relay Outputs
2 = Close and Stay Closed
3 = Continuous Pulse on and off (1
sec ON, 1 sec OFF)
08 = 24-Hr Aux
09 = Fire
10 = Interior w/Delay
39 = Any Fire Alarm
40 = Bypassing
41 = Mains Failure
42 = System Batt. Low
58 = Duress
7-5