VISTA-10SEa Installation and Setup Guide
• All Master and Secondary User codes permit access to the system for arming, disarming, etc.
• If a Secondary User code is inadvertently repeated for different users, the lower user number
will take priority.
• Opening and Closing reports are sent for the Master code as No. 02, with the appropriate
subscriber number. Secondary User codes are sent as Nos. 3 through 6 (or 8, if no Duress
code is assigned), respectively, with the appropriate subscriber number.
Duress Code
Important:
This code is useful only
when the system is
connected to a central
station.
To program a Duress code, enter:
Master code + CODE [8] + [8] + [desired 4-digit Duress code]
The keypad will beep once to confirm acceptance.
NOTE: The Duress code must differ from the Master code or any other user's code.
To change the duress code, enter:
Master code + [8] + [8] + [new 4-digit Duress code]
When the keypad beeps once, it signifies that the code has been changed.
To delete the Duress code, enter:
Master code + [8] + [8]
When the keypad beeps once, it signifies that the code has been deleted.

Keypad Functions

General Information
Note that if you enabled QUICK ARM (field
entering the security code, for any of the arming procedures (AWAY, STAY, INSTANT,
MAXIMUM, etc.). The security code is always required, however, when disarming the
system.
The Quick Arm feature will function only if the Master code has been programmed
(see "Assigning the Master Code" on the previous page).
The keypad allows the user to arm and disarm the system, and perform other system
functions, such as bypassing zones; and to display zone descriptors. Zone and system
conditions (Alarm, Trouble, Bypass) are displayed in the display window.
When an alarm occurs, keypad sounding and external sounding will occur, and the keypad
will display the zone(s) in alarm. Pressing any key will silence the keypad sounder for 10
seconds. Disarming the system will silence both keypad and external sounders. When the
system is disarmed, any zones that were in an alarm condition during the armed period will
be displayed (memory of alarm). To clear this display, simply repeat the disarm sequence
(enter the security code and press the OFF key) again.
The keypads also feature chime annunciation. Three Panic key pairs, or individual Panic
keys (depending on keypad type – see "Panic Keys" on next page), can send silent, audible,
Fire, or Personal Emergency alarms to the central station, if that service is connected.
Arming, Disarming Functions, etc.
The following is a brief list of system commands. For detailed information concerning system
functions, refer to the User's Manual.
15-2
This feature is intended for use when the user is forced to disarm or arm
the system under threat. When used, the system will act normally, but can
silently notify the central station of the user's situation, if that service has
been provided.
The Duress code may be any 4-digit code assigned to User No. 8.
and wait for the keypad to beep.
21), the [#] key can be pressed instead of