Installing Remote Keypads; Keypads That May Be Used; Wiring To The Keypads; Wiring Chart For Devices Drawing Aux Power From The Control - ADEMCO Vista-10SEa Installation And Setup Manual

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section

Keypads That May Be Used

Wiring to the Keypads

Mounting the Keypads
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Keypads That May Be Used
You may use up to 4 keypads, independent of auxiliary power considerations (you may need
to use an auxiliary power supply if the 500mA aux. output is exceeded). The following
keypad models may be used:
fixed-word display: 6128, 6128RF, 6137
alpha display: 6139
Be sure the keypads are set to the Non-addressable mode (address 31).
Wiring to the Keypads
1. Determine wire size by referring to the wiring length/size chart below.
For devices (keypads, RF receivers, expansion/relay units, etc.) connected to a single 4-
wire run, determine the current drawn by all units connected to the single wire run, then
refer to the "Wiring Chart" to determine the maximum wire length that can be safely
used for each wire size. Current drain for all devices can be found in Section 17:
SPECIFICATIONS AND ACCESSORIES.
NOTE: Refer to "Auxiliary Device Current Drain Worksheet" in Section 10: FINAL
You can also determine from the chart the maximum wire lengths for any device that is wired back
to the control, based on the current drain of that device alone.

Installing Remote Keypads

POWER-UP for current drain for all keypads.
Wiring Chart for Devices* Drawing Aux Power from the Control (12V+ & 12V–)
TOTAL CURRENT DRAIN OF ALL DEVICES CONNECTED TO A SINGLE WIRE RUN
Wire Size
50mA or less
0.64mm
150m
0.81mm
230m
1.0mm
400m
1.3mm
450m
*
Includes keypads, RF receivers, expansion/relay units, or the 4285/4286 Phone Module.
Supplementary Power for Additional Keypads
Preliminary Checkout Procedure
100mA
300mA
75m
25m
115m
40m
200m
65m
300m
100m
S E C T I O N
500mA
15m
25m
40m
70m
3
3-1