VISTA-10SEa Installation and Setup Guide
NOTE: If the communicator is in the process of sending a report to the central station,
The keypad will display all zone numbers of wireless units programmed into the system.
As the system receives a signal from each of the transmitters, the zone number of that
transmitter will disappear from the display. The transmitter codes may be checked
upon installation, or in an installed system.
disappear after about 1-1/2 hours.
To speed this process, you can physically fault and then restore all sensors.
NOTES:
Exit this mode by keying [Installer code] + OFF.
b. GO/NO GO TEST MODE
By pressing [Installer code]+ [#] + 4, you enter a mode similar to the user Test mode
(code + TEST), but the wireless receiver gain is reduced.
Checking in this mode assists in determining good mounting locations for the
transmitters when the system is being installed, and verifies that the RF transmission
has sufficient signal amplitude margin for the installed system.
Exit the mode by entering [Installer code] + OFF.
Regular maintenance and inspection (at least annually) by the installer and frequent testing
by the user are vital to continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular
maintenance program to the user, as well as acquainting the user with the proper operation
and limitations of the alarm system and its component parts. Recommendations must be
included for a specific program of frequent testing (at least weekly) to ensure the system's
proper operation at all times.
14-2
the system will not go into the Sniffer mode. In that case, wait a few minutes,
then try again.
All BR-type units must physically be activated to clear the display.
When one button of a transmitter (RF, UR, or BR) is activated, all zones assigned
to other buttons on that transmitter are cleared. This also applies to 5816 and
5817 Transmitters that have multiple loops (zones).
Any transmitter serial number that is not entered will not turn off its zone
number.

TO THE INSTALLER