Summary Of Connections - ADEMCO Vista-10SEa Installation And Setup Manual

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

(e.g. ADEMCO No. 90-12)
USE 12V, 6.5AH BATTERY FOR 500mA AUX
POWER. SEE INSTRUCTIONS.
SEALED LEAD ACID TYPE.
BLACK
BATTERY
+
RED
12V, 6.5AH
BATTERY NORMALLY
NEED NOT BE
CUT RED
JUMPER
REPLACED FOR AT
FOR BELL
LEAST 3 YRS.
SUPERVISION
TO DETERMINE TOTAL
STANDBY LOAD ON
BATTERY, ADD 100mA
1
2
TO TOTAL OF AUX.
POWER OUTPUT.
16.5VAC
1.5AMP
PLUGPACK
240VAC
N219
+
ALARM OUTPUT
12VDC, 2A MAX.
STEADY FOR
BURGLARY/PANIC,
PULSING FOR FIRE
BATTERY FUSE
FOR REPLACEMENT
USE SAME VALUE
THESE OPTIONAL ITEMS
3A
MAY ALSO BE USED
SEE THEIR INSTRUCTIONS
ADEMCO No. 5800TM
TRANSMITTER MODULE
(20mA)
(for No. 5827BD
Wireless Bidirectional Keypad)
+
BLK
RED
GRN
YEL
3
4
5
6
7
+
AUX. POWER
OUTPUT
12VDC
500mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
ALL CIRCUITS
ARE POWER
LIMITED.
NOTE:
KEYPAD
CURRENT
MUST BE
INCLUDED
IN AUX.
B R G Y
CURRENT
DRAIN
REMOTE
CALCULATIONS
KEYPAD
REMOTE KEYPADS
SYSTEM MUST BE
PROGRAMMED WITH A
6139. IT NEED NOT REMAIN IN
SYSTEM.
AFTER PROGRAMMING,
THE SYSTEM CAN USE:
6128RF (65mA),
6128 (25mA), 6137 (85mA),
OR 6139 (100mA).
MULTIPLE KEYPADS MAY BE
USED, BUT USE MAX. OF
67m OF 0.64mm WIRE OR
167m OF 1.0mm.
ADEMCO 5881 Type
RF RECEIVER (35mA)
WIRELESS ZONES
5881L:
UP TO 8
5881M/5881H:
UP TO 16
SET UNIT'S DIP SWITCH
FOR DEVICE ADDRESS OF "0"
(See receiver's instructions)
ADEMCO No. 4219
WIRED EXPANSION MODULE
(8 ADD'L EOLR WIRED ZONES)
OR
ADEMCO No. 4229
WIRED EXPANSION/RELAY MODULE
(8 ADD'L EOLR WIRED ZONES PLUS 2
OUTPUT RELAYS)
OR
ADEMCO No. 4204
RELAY MODULE (180mA MAX)
(4 OUTPUT RELAYS)
8
9
10
11
12
13
1000
1000
1000
1000
OHMS
OHMS
OHMS
OHMS
EOLR
EOLR
EOLR
EOLR
• MAXIMUM LOOP RESISTANCE (EACH ZONE): 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR
FAST RESPONSE TO AN OPEN: 10MSEC MAX
• ZONE 5 CAN BE PROGRAMMED FOR USE AS
A FIRE ZONE. SEE DIAGRAM.
WHEN THE CONTROL'S CIRCUIT BOARD IS INSTALLED IN ITS CABINET
Plug the provided small telephone transformer module into the two connectors on
the right side of the control board, component side inward (against the main board)
VISTA-10SE

SUMMARY OF CONNECTIONS

+
5
-
4
+
STROBE
STROBE DRIVE
-
250mA MAX.
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
TO HI SIDE
+
14
HEAT
ZONE 5
*
SET UNIT'S DIP
DETECTOR
SWITCH
-
15
FOR DEVICE
ADDRESS OF "1"
TO LO SIDE
(See unit's
*
IF PROGRAMMED FOR FIRE
instructions)
14
15
16
MODULAR
TELEPHONE
CONNECTOR
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
AT TELE COM 611 JACK BEFORE
1000
1000
OHMS
OHMS
SERVICING THIS UNIT.
EOLR
EOLR
AUSTEL
APPROVAL
A93/03/0327
.
R.E.N. = 0.8
a
+
RED
BLK
EOL
POWER
+
SUPER-
-
VISION
VIOLET
RELAY
MODULE
A77-716B
1000
OHMS
EOLR
17
LOCATED AT
LOWER RIGHT CORNER
OF CIRCUIT BOARD
EARTH
GROUND
SEE INSTRUCTIONS
FOR PROPER GROUNDING