Wired Zone Expansion (4219, 4229); Installing Zone Expansion Units; Connections And Setup - ADEMCO Vista-10SEa Installation And Setup Manual

Vista-10sea
Hide thumbs Also See for Vista-10SEa:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section

Installing Zone Expansion Units

Connections and Setup

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Installing Zone Expansion Units
You can add an 8-zone wired expansion EOLR unit to the control's 6 basic wired zones, for a
total of 14 wired zones, by using a No. 4219 Wired Expansion Unit or 4229 Wired Expan-
sion/Relay Unit.
Location
Supervision
Zone Information
Connections and Setup
1. Connect the 4219 or 4229 module to the control's keypad terminals (see diagram below).
2. Set the 4219 or 4229's DIP switch for device address "1" (switch 2 "OFF" and
switches 3, 4, 5 "ON"). Switch 1 determines expansion zone A's response time ("ON" =
normal response, "OFF" = fast response). For location of the DIP switch in either unit, see
the diagram below.
For additional information, see instructions supplied with the 4219 and 4229.
Wired Zone Expansion
Programming Wired Expansion Zones
Checkout Procedures for Wired Expansion Zones
You can mount an expansion unit within the control cabinet if
space permits. Otherwise, mount the unit outside the cabinet.
Units are supervised against removal. Keypads will display
"CHECK" and zone "09" if a zone expander is disconnected.
Units have tamper protection for security when mounted
outside of the cabinet.
Assign zone numbers 10–17 for the eight wired expansion
loops (designated A to H). You can program these zones
individually (in
"Programming Wired Expansion Zones" later in this section.