Advertisement

Quick Links

N7227PRGDV3 6/01
V
V
OFF
AWAY
1
2
OFF
MAX
TEST
ON
4
5
INSTANT
CODE
7
8
READY
*
0
PANIC
I
S
T
A
I
S
T
A
Security System
Programming Guide
ARMED
READY
STAY
3
BYPASS
6
CHIME
9
#
®
-
1
0
S
E
-
1
0
S
E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VISTA-10SE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADEMCO VISTA-10SE

  • Page 1 Security System Programming Guide ARMED READY AWAY STAY TEST BYPASS INSTANT CODE CHIME READY PANIC ® N7227PRGDV3 6/01...
  • Page 2 - 2 -...
  • Page 3: Table Of Contents

    Table of Contents • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Programming Guide ................5 System Setup....................
  • Page 4 - 4 -...
  • Page 5: Programming Guide

    Programming Form Local programming requires the use of a 2-line alpha keypad (e.g., 6139) connected to the keypad terminals on the control. To set all program fields to ADEMCO default values: Press 97. Field Function ] = Default Value Programmed Values...
  • Page 6: Zone Assignment/Alarm Report Codes

    5 - 2 5 * * * , T r o u b l e s 3 = 4+2 RADIONICS STANDARD Can only be used if Primary reporting is ADEMCO Contact ® . 6 or undefined = 4+2 ADEMCO EXPRESS ®...
  • Page 7: Rf Expansion Zones

    RF EXPANSION ZONES: Assign zone numbers (Zn) 10–25 to 5881L (up to 8); 5881M or 5881H (up to 16). NOTE: All numbers in brackets [ ] are default settings ZONE ZONE ZONE ALARM RPT CODE INPUT LEARNED DESCRIPTION TYPE (Hex) TYPE RF INPUT (Zn)
  • Page 8: System Status Report Codes

    A 0 (not #+10) in both boxes will disable the report. user number if expanded or 4+2 reporting is selected. With ADEMCO Contact ID ® Reporting: Enter any digit (other 2nd digit of EXIT ALARM REPORT is automatically sent as...
  • Page 9: Download Information

    95, if entering next field). To clear ACCOUNT NO. FOR INITIAL DOWNLOAD. entries from this field, press 94 No data entry required. 97 SETS ALL PROGRAM FIELDS TO ADEMCO DEFAULT VALUES. No data entry required. EXITS ( 98, 99) Exits programming mode and prevents re-entry Exits programming mode and allows re-entry by: by: Installer Code + 8+ 0.
  • Page 10: Output Relays Worksheet

    OUTPUT RELAYS WORKSHEET FOR FIELDS 80 and 81. Applicable only if 4204 relays are to be used. 80 OUTPUT RELAYS – This is an Interactive Menu mode. Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data in response to the displays and prompts that appear in sequence.
  • Page 11: Alpha Vocabulary List

    ALPHA VOCABULARY LIST (For Entering Zone Descriptors) NOTE: Some rarely used words appearing in previously published lists have been deleted from the list below. Use only this list for selecting zone descriptors. (Word Space) • 057 DOOR • 207 UPSTAIRS •...
  • Page 12: Enrolled Transmitters

    SYSTEM ENROLLED TRANSMITTERS ZONE SERIAL NO. (If applicable) INPUT Stick Serial No. Label from Transmitter ZONE ZONE LOOP TYPE Here TYPE DEVICE LOCATION – 12 –...
  • Page 13: 5800 Series Transmitter Input Loop Identification

    LOOP 3 LOOP 2 LOOP 1 (REED) (PRIMARY) LOOP 2 LOOP 2 (AUX. CENTER) LOOP 1 LOOP 1 LOOP (TERMINALS) LOOP 3 LOOP 4 (AUX. RIGHT) ALTERNATE YOU MUST POSITION 5 8 1 7 ENROLL THIS 5 8 1 6 M N FOR LOOP 2 ENROLL AS "RF"...
  • Page 14 NOTES – 14 –...
  • Page 15: Summary Of Connections Diagram

    VISTA–10SE SUMMARY OF CONNECTIONS DIAGRAM – 15 –...
  • Page 16 165 Eileen Way, Syosset, New York 11791 Copyright © 2001 PITTWAY CORPORATION !"#$$#%&'()*+,- N7227PRGDV3 06/01...

Table of Contents