VISTA-10SEa Installation and Setup Guide
Whichever entry is used to start the action cannot also be used to stop it. The opposite action
must be performed either by the other keypad entry or by some other event or operation offered in
the programming section.
If a relay is energized before a 4-wire smoke detector is reset, the relay will be stopped by the
interruption of Aux. Power that resets the smoke detector. If this is not desired, the power to the
relay unit should be supplied from another 12V power source (e.g., the same source that is
powering external equipment through the relay contacts).

Programming Output Relays

1. With at least one 2-line alpha keypad (6139) connected to the keypad terminals on the
control, power up the system temporarily. If you previously connected the mains
plugpack to the control panel, you need only plug in the plugpack (to 230VAC outlet) to
power up the system.
2. Enter the Programming mode by keying the following on the alpha keypad:
Installer code (4 1 1 1) + 8 + 0.
You must program field 25 WIRED EXPANSION/RELAY USED as required before continuing
(i.e., 2 = 4229, 3 = 4204).
3. Press
program all output relays used in the system (4204 or 4229 modules). Refer to the
Programming Form worksheet in the separate Programming Guide for 80 Interactive
mode. If field 25 has not been programmed for a 4204 or 4229 relay, skip this field.
Output Relay Displays
Enter Relay No.
(00 = Quit)
02
STT 0
7-4
to deactivate.
If you choose a "SYSTEM OPERATION," that operation will cause the relay
to deactivate.
If the system uses relay outputs, two keypad entries available to the user
are included among the "System Operation" choices that may be
programmed (34 and 35). They can manually activate or deactivate the
relay(s) for starting or stopping some action, such as turning lights on or off,
etc.
These entries are:
80. Note that this is an Interactive menu programming mode. It is used to
When you press 80, this screen will appear.
Enter the Relay Number 01, 02, 03, or 04 for a 4204; or 01
01
or 02 for a 4229 (or 00 to end these entries).
Press [ ] to continue.
The [ ] key is used to accept an entry and advance to the
next prompt.
The [#] key is used to revert back to the last question to
check or change an entry. Press [ ] to go forward again.
This screen displays a summary of the current relay START
A EV ZL ZT
programming (for this example, relay 02 has been selected).
0
0 00
Press [ ] to continue.
[Security code] + [#] + 7
and [Security code] + [#] + 8