VISTA-10SEa Installation and Setup Guide
Standard Phone Line Connections
The wiring connections shown here are not applicable if the 4285/4286 Phone Module is used.
Refer to Section 8: 4285/4286 PHONE MODULE for information regarding phone line
connections, which are different than those shown here.
Incoming phone line and local telephone wiring is connected to the panel's modular
connector via a 611 jack, as shown in Figure 2–4.
CONTROL BOARD
Wiring the AC Transformer
Wire the mains plugpack transformer to terminals 1 and 2 on the control board. See the
wiring table below for wire size to use.
Wiring to the AC mains plugpack must not exceed 75m using 1.3mm wire. Do not plug the
plugpack into the mains outlet until you are instructed to do so later in the manual.
2-4
MODULAR
TELEPHONE
CONNECTOR
MODULAR
TELEPHONE
CONNECTOR
Figure 2–4. Standard Telephone Line Connections
Wiring Table
Distance of Transformer
From Control Panel
Up to 15m
15-30m
30-75m
INCOMING TELECOM LINE
DIRECT
CONNECT
TIP
CORD
611
RING
JACK
PLUG
Wire Size to Use
.8mm
1mm
1.3mm
PREMISES
ANSWERING
MACHINE AND
PHONE(S)
ANSWERING
MACHINE