VISTA-10SEa Installation and Setup Guide
Supervision
The 4204 and 4229 modules are supervised against removal. The keypad will display
"CHECK" and zone "09" if a module is disconnected from the control's keypad terminals (4,
5, 6, and 7).
RELAY
CONNECTOR
RLY
2
RELAYS
"OFF"

Programming Options Defined

The following will help you understand the programming of output relays when you are
using 80 and 81 Interactive menu modes. The options used to start and stop relays are
described below, followed by the actual screen prompts and available entries.
The letter(s) in parentheses after each function described below, such as (A) after ACTION,
are those that appear in the various summary displays of programmed data during
programming.
ACTION (A) The "ACTION" of the relay is how the relay will respond when it is activated
7-2
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
Figure 7–1. 4204 Connections to Control
RELAY
2
}
RELAY
1
NO C NC
}
TAMPER JUMPER POSITION
4229 IN CABINET
(NOT TAMPERED)
4229 REMOTE
(TAMPER PROTECTED)
1
2
RLY
REED
1
(TAMPER)
SWITCH
1K
A
B
ZONES:
Figure 7–2. 4229 Connections to Control
by the "START" programming. You may want the relay to activate
momentarily, to pulse on and off continuously, or to remain activated until
some other event occurs to stop it. There are four different choices of actions:
4-PIN CONSOLE PLUG
EITHER OR BOTH
CAN BE USED
TB1
13 14 15 16
YEL
BLK
GRN
RED
DIP SWITCH
FOR SETTING ADDRESS
AND ZONE "A" RESPONSE
EITHER OR BOTH CAN BE USED
4-PIN CONSOLE PLUG
TB1
3
4
5
6
7
8
9
10 11 12
C
D
E
F
G
RELAY
4
TYPICAL
(SHOWN "OFF")
RELAY
3
RELAY
2
RELAY
1
DATA IN
FROM CONTROL
(–) GROUND
DATA OUT
TO CONTROL
(+) 12V
4229
4229
TB2
GRN DATA OUT
4
TO CONTROL
BLK
(–) GROUND
4
3
3
RED
(+) 12V
2
2
YEL DATA IN
1
1
FROM
CONTROL
TERMINATE EACH
PROGRAMMED ZONE
WITH 1000 OHM (1K)
END-OF-LINE RESISTOR
(EACH ZONE'S MAX.
LOOP RESISTANCE:
300 OHMS + E.O.L.)
H
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
TB2
TERMINALS ON
CONTROL PANE
(TERM 6)
(TERM 4)
(TERM 5)
(TERM 7)