Cover Top Side R - Epson AcuLaser CX11 Service Manual

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F

4.2.2.5 COVER TOP SIDE R

REMOVAL
1.
Open the COVER FUSER.
(p311)
2.
Open the COVER ASSY TOP.
3.
Remove the screw (silver, with flange, 8 mm) fastening the COVER TOP SIDE R
to the main unit.
4.
Remove the COVER TOP SIDE R from the main unit.
REINSTALLATION
1.
Match the hole on the COVER TOP SIDE R with the boss on the main unit.
2.
Fasten COVER TOP SIDE R to the main unit with the screw (silver, with flange, 8
mm).
3.
Close COVER ASSY TOP.
4.
Close COVER FUSER.
(p321)
DISASSEMBLY AND ASSEMBLY
Figure 4-8. Removal of COVER TOP SIDE R
Printer
Revision B
4)
3)
Leg_Sec03_503EA
313

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aculaser cx11f

Table of Contents