Bcr Cln Xero Assy - Epson AcuLaser CX11 Service Manual

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F

4.2.6.9 BCR CLN XERO ASSY

REMOVAL
1.
Remove COVER ASSY RH.
(p326)
2.
Remove FRAME ASSY-PH.
(p352)
3.
Disconnect connector (P/J617) from BCR CLN XERO ASSY on the right side of
the main unit.
4.
Unclamp the clamp on the right side of the main unit, and move the harness on
BCR CLN XERO ASSY to inside the main unit from the hole on the right side of
the main unit.
When performing the following work, press LATCH ROTARY on
C A U T I O N
LATCH ASSY-ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent
contact with MAG ROLL.
5.
Remove the 2 screws (silver, with flange, 6 mm) fastening BCR CLN XERO
ASSY to the main unit.
6.
Remove BCR CLN XERO ASSY from the main unit.
REINSTALLATION
1.
Match the boss on BCR CLN XERO ASSY with the hole on the main unit, and
attach BCR CLN XERO ASSY.
When performing the following work, press LATCH ROTARY on
C A U T I O N
LATCH ASSY-ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent
contact with MAG ROLL.
2.
Fasten BCR CLN XERO ASSY to the main unit with the 2 screws (silver, with
flange, 6 mm).
DISASSEMBLY AND ASSEMBLY
3.
Take out the harness of BCR CLN XERO ASSY to the outside from the hole on
the right side of the main unit, and connect connector (P/L617) for BCR CLN
XERO ASSY to the harness.
4.
Fasten the harness on BCR CLN XERO ASSY with the clamp on the right side of
the main unit.
5.
Attach FRAME ASSY-PH.
6.
Attach COVER ASSY RH.
4)
4)
3)
Figure 4-85. Removal of BCR CLN XERO ASSY
Printer
(p352)
(p326)
6)
5)
5)
Leg_Sec03_084EB