CLEANING
There is no part to be cleaned regularly in the AcuLaser CX11/CX11F. The following
describes the procedure to clean certain parts which should be cleaned on an as-needed
basis.
Do not use chemical solvent such as thinner, benzine, acetone
C A U T I O N
to clean the housing or any other exterior part of the product.
Doing so may deteriorate or deform those parts.
Be careful not to get the internal components wet when
cleaning.

Cleaning the Pick Up Roller

1.
Open the MP Tray Cover and take out the loaded papers.
2.
Wipe the rubber part of the Pick Up Roller using a clean soft cloth moistened with
water.
When cleaning the Pick Up Roller, be careful not to damage the
C A U T I O N
actuator placed in front of the Feed Roller
Figure 6-2. Cleaning the Pick Up Roller
MAINTENANCE

Cleaning the Exposure Window

1.
Open the cleaner cover on the right side of the product, and open Cover A.
2.
Pull the lever placed right inner side of the product in the direction of the arrow.
Cover A
3.
Slowly pull the cleaner outward and push it back. (1 cycle)
C A U T I O N
Feed Roller
Actuator
4.
Push the lever back to its original position.
On-site Service
Cleaner Cover
Figure 6-3. Cleaning the Exposure Window (1)
To clean the printhead properly, pull the cleaner until it do not
move anymore, and push it back as far as it will go.
Figure 6-4. Cleaning the Exposure Window (2)
Revision B
Lever
Cleaner