REINSTALLATION
Be sure to lubricate the specified locations after reinstalling the
A D J U S T M E N T
R E Q U I R E D
DOC.ADJUST L/R and TRAY GEAR 24T, or replacing them with
new ones.
Refer to Section
"6.3.2.2 Lublication"
1.
Put the DOC. ADJUST L through the hole of the DOC. PAPER GUIDE and attach
the DOC. ADJUST L to the groove on the GEAR PLATE.
2.
Put the DOC. ADJUST R through the hole of the DOC. PAPER GUIDE and
attach the DOC. ADJUST R to the groove on the GEAR PLATE.
3.
Move the two GEAR PLATEs so that the gap between them becomes smallest,
and attach TRAY GEAR 24T to the DOC. PAPER GUIDE.
4.
Secure the TRAY COVER to the DOC. PAPER GUIDE with the two screws (M3
x 8 mm, P-type, A-head).
5.
Attach the PAPER GUIDE ASSY.
6.
Attach the ADF COVER R.
(p492)
7.
Attach the ADF Unit.
(p481)
8.
Install the Scanner.
(p306)
DISASSEMBLY AND ASSEMBLY
(p551).
(p526)
DOC. PAPER GUIDE
Figure 4-223. Reinstallation of GEAR PLATE, TRAY GEAR 24T, DOC.ADJUST L/R
ADF Section
manuals4you.com
manuals4you.com
GEAR PLATE
Attach TRAY GEAR 24T
with the smallest gap
between two GUIDE
PLATEs.