4.2.4.15 DRIVE ASSY-PH

REMOVAL
1.
Remove FRAME ASSY-PH.
(p352)
2.
Remove MOTOR-PH.
(p362)
3.
Unclamp the clamp on DRIVE ASSY-PH, and remove the harness.
4.
Remove the 2 screws (silver, with flange, tapping, 8 mm) fastening DRIVE
ASSY-PH to FRAME ASSY-PH.
5.
Remove DRIVE ASSY-PH from FRAME ASSY-PH.
REINSTALLATION
When performing the following work, make sure that the gears on
C A U T I O N
CLUTCH ASSY REGI and CLUTCH ASSY PRE REGI are
correctly engaged.
1.
Match the hole on DRIVE ASSY-PH with the boss on FRAME ASSY-PH, and
attach DRIVE ASSY-PH.
2.
Fasten DRIVE ASSY-PH to FRAME ASSY-PH with the 2 screws (silver, with
flange, tapping, 8 mm).
3.
Fasten the harness with the clamp on DRIVE ASSY-PH.
4.
Attach MOTOR-PH.
(p362)
5.
Attach FRAME ASSY-PH.
(p352)
DISASSEMBLY AND ASSEMBLY
CLUTCH ASSY REGI
5)
4)
4)
Figure 4-57. Removal of DRIVE ASSY-PH
Printer
Revision B
3)
Leg_Sec03_069FA
CLUTCH ASSY PRE REGI
365