EPSON AcuLaser CX11/CX11F

4.2.9 FUSER

4.2.9.1 FUSER ASSY
Be extremely careful not to burn your hand when handling the
C A U T I O N
FUSER section.
REMOVAL
FUSER ASSY
1.
Open COVER FUSER.
2.
Release the COVER TOP SIDE L from the hook of the COVER FUSER GUIDE,
and turn the COVER FUSER GUIDE 90 degrees in the direction of the arrow.
3.
Move the levers on both sides of the FUSER ASSY upward to unlock and remove
the FUSER ASSY.
Actuator
4.
Pull out the shaft of the Actuator with the Chute of the FUSER ASSY opened, and
remove the Actuator together with the Spring.
5.
Remove the Spring from the Actuator.
DISASSEMBLY AND ASSEMBLY
COVER FUSER GUIDE
COVER TOP
SIDE L
Hook
Figure 4-99. Removal of FUSER ASSY
Printer
2)
3)-1
3)-2
Revision B
3)-1