EPSON AcuLaser CX11/CX11F
REINSTALLATION
Actuator
1.
Attach the Spring to the Actuator.
2.
Insert the shaft of the Actuator with the Chute of the FUSER ASSY opened, and
attach the Actuator together with the Spring.
FUSER ASSY
3.
Attach the FUSER ASSY to the main unit matching the connector and boss of the
FUSER ASSY with the connector and the hole of the main unit, and push the
levers on the both sides of the FUSER ASSY to secure it to the main unit.
4.
Return the COVER FUSER GUIDE to its original position, and secure the
COVER TOP SIDE L with the hook of the COVER FUSER GUIDE.
5.
Close COVER FUSER.
Be sure to reset the life counter of the FUSER ASSY after replacing
C A U T I O N
it with a new one.
(See
" 6.4.1.1 Maintenance Menu Items "
DISASSEMBLY AND ASSEMBLY
(p553))
Printer
manuals4you.com
manuals4you.com
5)
4)-2
Figure 4-100. NIP Release Lever Fixing Parts
Revision B
4)-1
Leg_Sec03_160EA
416