Fip-32 - Epson AcuLaser CX11 Service Manual

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F

FIP-32

Panel Message
Check Transparency
Possible parts that caused the error
SENSOR OHP
HARNESS-ASSY P/H2
HARNESS ASSY MAIN
Troubleshooting
Step
Check
Check of transparency setting
1
Does the transparency in use match the
NVRAM setting (which type of transparency
(with or without white margin) is enabled or
disabled.)
Does the error recur when a test print is
2
made?
Check of dirt and foreign bodies on surface
3
of SENSOR OHP
Open COVER-P/H.
Are there any dirt or foreign bodies on the
SENSOR surface?
Does the error recur when a test print is
4
made?
Operation check of SENSOR OHP
5
The voltage of P408-8 ↔ P408-7 on PWBA
MCU is 5 VDC when white paper is brought to
the sensor sensing area (transparency must not
be used), and becomes 0 VDC when paper is
removed?
TROUBLESHOOTING
HARNESS-ASSY P/H1
PWBA MCU
LV/HVPS
Yes
No
Go to Step [3].
Replace the
transparency in
use with a one
that matches the
NVRAM
settings, or
change the
NVRAM setting
and go to [2].
Go to Step[3].
End of procedure
Clean to remove
Go to Step [5].
any dirt or
foreign bodies,
and go to step
[4].
Go to Step[5].
End of procedure
Replace PWBA
Go to Step [6].
MCU.
(p.432)
manuals4you.com
manuals4you.com
Step
Check
Power supply check to SENSOR OHP
6
Disconnect the P/J408 from PWBA MCU.
The voltage of P408-9 ↔ P408-7 on PWBA
MCU is 5 VDC?
Continuity check of HARNESS-ASSY P/H1
7
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-7 ↔ J603-6
J408-8 ↔ J603-5
J408-9 ↔ J603-4
Continuity check of HARNESS-ASSY P/H2
8
Disconnect the P/J603 from PWBA MCU.
Do all of the wiring below have normal
continuity?
P603-7 ↔ J101-3
P603-8 ↔ J101-2
P603-9 ↔ J101-1
5 VDC power supply check to PWBA MCU
9
The voltage of P410-3 ↔ P410-4 on PWBA
MCU is 5 VDC?
Continuity check of HARNESS ASSY MAIN
10
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3 ↔ J502-3
J410-4 ↔ J502-4
Printer
Revision B
Yes
No
Go to Step [7].
Go to Step [9].
Go to Step [8].
Replace
HARNESS-
ASSY P/H1.
Replace
Replace
SENSOR OHP.
HARNESS-
(p.359)
ASSY P/H2.
Replace PWBA
Go to Step [10].
MCU.
(p.432)
Replace LV/
Repair broken or
HVPS.
(p.435)
shorted part.