4.2.4.9 SENSOR OHP

REMOVAL
1.
Remove FRAME ASSY-PH.
(p352)
2.
Remove the screw (silver, with flange, tapping, 8 mm) fastening BRACKET-
SENSOR OHP to FRAME ASSY-PH.
When performing the following work, take care not to remove
C A U T I O N
FRAME ASSY-PH and BRACKET-SENSOR OHP too far as they
are connected by harnesses.
3.
Remove BRACKET-SENSOR OHP together with SENSOR OHP from FRAME
ASSY-PH.
4.
Disconnect connector (P/J101) from SENSOR OHP.
5.
Remove the screw (silver, tapping, 8 mm) fastening SENSOR OHP to
BRACKET-SENSOR OHP.
6.
Remove SENSOR OHP from BRACKET-SENSOR OHP.
REINSTALLATION
1.
Match the boss on SENSOR OHP with the hole on BRACKET-SENSOR OHP,
and attach SENSOR OHP to BRACKET-SENSOR OHP.
2.
Fasten SENSOR OHP to BRACKET-SENSOR OHP with the screw (silver,
tapping, 8 mm).
3.
Connect connector (P/J101) to SENSOR OHP.
4.
Match the hole on BRACKET-SENSOR OHP with the boss on FRAME ASSY-
PH, and attach BRACKET-SENSOR OHP together with SENSOR OHP.
5.
Fasten BRACKET-SENSOR OHP to FRAME ASSY-PH with the screw (silver,
with flange, tapping, 8 mm).
6.
Attach FRAME ASSY-PH.
(p352)
DISASSEMBLY AND ASSEMBLY
Figure 4-51. Removal of SENSOR OHP
Printer
Revision B
2)
5)
3)
4)
Leg_Sec03_062FA
6)
359