6.4 Printer Maintenance Function

6.4.1 Maintenance Menu

This menu is provided only for a service personnel to perform
C A U T I O N
maintenance. It must not be disclosed to the users.
This menu is displayed and selectable only when a special operation performed at
power-on to enter the maintenance mode. Basically, this menu is provided to be used
by a service personnel for maintenance.
At the time of maintenance, print the Engine Status Sheet from the Maintenance Menu
and grasp the usage conditions of various consumables and components needing
periodic replacement.

6.4.1.1 Maintenance Menu Items

This menu is displayed and selectable only when a special operation performed at
power-on to enter the maintenance mode.
When the power is then turned off once and on again, the Maintenance Menu is deleted
(the printer returns to the normal operating mode).
Engine Status Sheet
(p555)
Press the [Right
] button to print the Engine Status Sheet.
Before entering the maintenance mode, make sure that an engine-related service
call error is not occurring in normal operating mode (not maintenance mode). The
sheet is printed according to the default settings, except RIT, toner save, and
resolution settings (current settings are applied for those settings), and others are
printed according to the factory settings.The user default environment (settings)
does not change after the printing. While the printing is in progress, the LCD
keeps flashing.
The contents of the engine status sheet are the counted values of each unit which
makes up the printer engine.
Print Log Report
(p560)
Prints a log file of printing status.
MAINTENANCE

Reset 2ndBTRCounter

Resets the life counter of the 2nd BTR ASSY.
After executing the counter reset, open and close the Cover A, and do not turn the
printer off until the engine stops completely.
The counter must be reset after the 2nd BTR ASSY is replaced with a new one.
When resetting the counter, the number of printed pages for the previous 2nd BTR
ASSY at that point is stored in the engine.The stored value will be printed on the
Engine Status Sheet as the number of previous replacement.
Reset Y (M, C, K) DvlpCounter
Resets the life counter of the Housing ASSY-DEVE.
After executing the counter reset, open and close the Cover A, and do not turn the
printer off until the engine stops completely.
The counter must be reset after the Housing ASSY-DEVE is replaced with a new
one.
Reset Fuser Counter
Resets the life counter of the FUSER ASSY.
The counter must be reset after the Fuser unit is replaced with a new one.
When resetting the counter, the number of printed pages for the previous FUSER
ASSY is stored in the engine. The stored value will be printed on the Engine Status
Sheet as the number of previous replacement.
Clear Error Log
Clears error log list stored in the engine to print on Engine Status Sheet.
Performing this operation reboots the printer.
MCU DATA BackUp
Backups the data stored on the NVM in the engine controller.
"MCU Data BackUp" is displayed while the backup is in progress.
MCU DATA Restore
Restores the backup data made by "MCU DATA Backup" on the NVM in the
engine controller.
"MCU DATA Backup" is displayed while the restoring is in progress.