Epson AcuLaser CX11 Service Manual page 653

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F
Maintenanc
e Code
Label
Main Sub
COM_V29_EPTONE
310
COM_BYTE_DIS_DTC
310
COM_CTC_NUM
310
COM_T5_TIME
310
COM_EQM_48
310
COM_EQM_72
310
COM_EQM_96
310
COM_EQM_120
310
COM_EQM_144
310
COM_EQM_TCM72
310
COM_EQM_TCM96
310
COM_TX_CODE
310
COM_RX_CODE
310
COM_V34_GAIN_CHG
310
APPENDIX
Table 7-19. List of System Parameter (Communication Control)
User
Internal
Access
Address
---
Enables or disables superimposing V.29 EP-tone
060
0D0
Set whether superimpose or not superimpose EP-tone to V.29 tones
based on the ITU-T G3 standard.
---
061
0D1
Number of bytes for transmitting FIF of DIS/DTC
DTC: Transmit command corresponds to DIS.
---
062
0D2
Number of transmitting CTC
---
063
0D3
ECM T5 timer
Timer for RNR signal sent from the receiving machine when the
receiving machine cannot continue to receive a fax due to
insufficient memory or any other troubles.
---
064
0D4
EQU comparison value at 4800 bps
---
EQU comparison value at 7200 bps
065
0D5
---
EQU comparison value at 9600 bps
066
0D6
---
067
0D7
EQU comparison value at 12000 bps
---
068
0D8
EQU comparison value at 14400 bps
---
069
0D9
EQU comparison value at TCM 7200 bps
---
070
0DA
EQU comparison value at TCM 9600 bps
---
071
0DB
Encoding method for transmission
Changes the method according to the receiving machine
performance.
---
072
0DC
Encoding method for reception
---
073
0DD
Gain switching mode when detecting V.34 tones
Description
Fax Unit System
Setting Value
0 = Disable
1 = Enable
0 = 4 bytes system
1 = 5 bytes system
2 = 6 bytes system
3 = 7 bytes system
4 = 8 bytes system
5 = 9 bytes system
6 = 10 bytes system
7 = 11 bytes system
8 = 12 bytes system
9 = 13 bytes system
10 = 14 bytes system (maximum capacity)
0=000 to 7=111
0 to 255 sec (1 step = 1 sec)
0 to 0x7F FTT transmitting criterion
0 to 0x7F FTT transmitting criterion
0 to 0x7F FTT transmitting criterion
0 to 0x7F FTT transmitting criterion
0 to 0x7F FTT transmitting criterion
0 to 0x7F FTT transmitting criterion
0 to 0x7F FTT transmitting criterion
0 = MH
1 = MR
2 = MMR
3 = JBIG(Not used)
0 = MH
1 = MR
2 = MMR
3 = JBIG(Not used)
0 = Not switch the gain
1 = Switches the gain
Revision B
Remark
Default
s
Disable
---
(0)
---
10bytes
(6)
---
5
---
65 seconds
(65)
---
0x3A
0x32
---
0x3A
---
---
0x4F
---
0x3F
---
0x48
---
0x4E
---
MMR
(2)
---
MMR
(2)
---
Switches
(1)
655