EPSON AcuLaser CX11/CX11F

4.4.2.6 CONNECTOR UNIT ACEMU

REMOVAL
1.
Remove the Scanner.
(p306)
2.
Remove the ADF Unit.
(p481)
3.
Remove the ADF COVER R.
(p492)
4.
Remove the PAPER GUIDE ASSY.
5.
Remove the ADF COVER C.
(p496)
6.
Remove the ADF BASE ASSY.
7.
Remove the E CLUTCH UNIT.
8.
Remove the SENSOR LEVER.
(p507)
9.
Release the harnesses of the CONNECTOR UNIT ACEMU from the notch of the
ADF BASE.
10. Release the CONNECTOR UNIT ACEMU from the tab of the ADF BASE to
remove the CONNECTOR UNIT ACEMU.
REINSTALLATION
1.
Push the CONNECTOR UNIT ACEMU into the place on the ADF BASE and
secure it with the tab of the ADF BASE.
2.
Route the harnesses of the CONNECTOR UNIT ACEMU as shown in the figure,
and secure them with the notch on the ADF BASE.
3.
Attach the SENSOR LEVER.
(p507)
4.
Attach the E CLUTCH UNIT.
(p501)
5.
Attach the ADF BASE ASSY.
(p498)
6.
Attach the ADF COVER C.
(p496)
7.
Attach the PAPER GUIDE ASSY.
8.
Attach the ADF COVER R.
(p492)
9.
Attach the ADF Unit.
(p481)
DISASSEMBLY AND ASSEMBLY
(p526)
(p498)
(p501)
(p526)
10. Install the Scanner.
(p306)
Figure 4-194. Removal of CONNECTOR UNIT ACEMU
ADF Section
manuals4you.com
manuals4you.com
9)
10)
CONNECTOR UNIT ACEMU
ADF BASE
Revision B
508