Overcurrent Protection; Overvoltage Protection; Power Save; Stopping Output By Interlock Switch - Epson AcuLaser CX11 Service Manual

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F
1. DC POWER SUPPLY

Overcurrent Protection

All outputs (+24VDC, +5VDC, +3.3VDC) from LV/HVPS are stopped when
short-circuiting on the way to the earth or ground. Each output is restored by
eliminating the cause of the short-circuit, and turning the printer OFF and then
back ON at specified time interval. The overcurrent protection circuit is activated
when a current exceeds 16A flows.

Overvoltage Protection

All outputs from LV/HVPS are stopped when an overvoltage is detected. The
operating voltages for overvoltage protection of each output are as follows:
+24VDC: 36VDC
+5VDC: 7VDC
+3.3VDC: 5VDC

Power save

Name of Signal Line
Signal for turning +24VDC OFF
POWER SAVE

Stopping output by Interlock Switch

Name of Signal Line
I/L +5VDC
The I/L +5VDC signal that arrives via Front Interlock Switch, Upper
Interlock Switch and Fuser Interlock Switch becomes the power source of the
LV/HVPS internal Relay coil. This signal opens/closes Relay contacts, and
controls INTERLOCK +24VDC and INTERLOCK +5VDC.
APPENDIX
Remarks
Remarks
---
Printer System Electrical Connection
manuals4you.com
manuals4you.com
LV/HVPS
PL12.2.3
P/J500
3
Power
Save
4
P/J502
P/J115
+5VDC
13
1
3
I/L +5VDC
15
+5VDC
+5VDC
P/J500
Supply
5
P/J502
3
4
+24VDC
+24VDC
Supply
5
6
7
8
+3.3VDC
+3.3VDC
Supply
1
2
9
10
11
12
P/J503
3
1
Figure 7-8. DC POWER SUPPLY Connection and Wiring Diagram
Revision B
PWBA MCU
PL12.2.1
P/J401
POWER SAVE
20
19
SWITCH
SWITCH-
ASSY
INLK
TOP
FRONT
P/J115
P/J116
P/J116
PL.1.1.27
PL.1.1.7
1
3
1
3
1
3
SWITCH-
INLK
FUSER
PL.1.1.34
P/J117
P/J117
3
1
3
1
PWBA MCU
PL12.2.1
P/J401
Interlock
I/L +5VDC
18
+5VDC
P/J410
+5VDC
+5VDC
3
SG
4
INTERLOCK
+24VDC
I/L +24VDC
5
I/L +24VDC
6
SG
7
SG
8
+3.3VDC
+3.3VDC
1
SG
2
MOT ASSY P/R
PL11.1.6
Interlock
P/J201
+24VDC
I/L +24VDC
1
SG
2
PWB ASSY
ROT
PL12.1.10
P/J432
Interlock
I/L +24VDC
1
+24VDC
SG
3
PWBA FUSER CONTROL
PL12.2.12
P/J2
3
1
Leg_Sec007_002FB