Epson AcuLaser CX11 Service Manual page 380

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F
4.2.5.9 SENSOR 2BTR RETRACT
REMOVAL
1.
Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
2.
Disconnect connector (P/J112) from SENSOR 2BTR RETRACT.
3.
Remove the screw (silver, with flange, 8 mm) fastening BRACKET-SENSOR
PHOTO to the main unit.
4.
Remove BRACKET-SENSOR PHOTO from the main unit together with
SENSOR 2BTR RETRACT.
5.
Unhook the three hooks fastening SENSOR 2BTR RETRACT to BRACKET-
SENSOR PHOTO, and remove SENSOR 2BTR RETRACT.
REINSTALLATION
1.
Match the hooks on SENSOR 2BTR RETRACT with the attachment position, and
attach to BRACKET-SENSOR PHOTO.
2.
Match the hole on BRACKET-SENSOR PHOTO with the boss on the main unit,
and attach BRACKET-SENSOR PHOTO together with SENSOR 2BTR
RETRACT.
3.
Fasten BRACKET-SENSOR PHOTO to the main unit with the screw (silver, with
flange, 8mm).
4.
Connect connector (P/J112) to SENSOR 2BTR RETRACT.
The shutter of CAM ASSY-2ND must be inserted inside the sensor
C A U T I O N
on SENSOR 2BTR RETRACT.
5.
Attach CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
DISASSEMBLY AND ASSEMBLY
(p366)
(p366)
Printer
manuals4you.com
manuals4you.com
CAUTION
Figure 4-69. Removal of SENSOR 2BTR RETRACT
Revision B
5)-2
2)
4)
3)
5)-1
Leg_Sec03_073RB