Before starting troubleshooting, inspect the feed path of the printer paper. Check the
paper feed path for metal staples, paper clips, paper scraps, and other foreign matter.
Step
Check
Check of laser beam path
1
Are there any obstructions between ROS ASSY
and Photoconductor Unit?
Is ROS window completely covered by
2
obstacles, or is it dirty?
Check connection of ROS ASSY connector
3
Is the connector firmly connected to ROS
ASSY?
TROUBLESHOOTING
Problems
Completely blank pages are printed.
ESS and possible parts that caused the error
Photoconductor Unit
ROS ASSY
Toner Cartridge Y
Toner Cartridge M
Toner Cartridge C
Toner Cartridge K
2ND BTR ASSY
HOUSING ASSY-GUIDE AD
MOTOR ASSY MAG
PWBA ESS
PWBA MCU
LV/HVPS
FUSER ASSY
500 FEEDER ASSY OPTION
Yes
No
Remove
Go to Step [2].
obstacles.
Remove
Go to Step [3].
obstacles, and
clean ROS
window with
CLEANER
ASSY.
Go to Step [4].
Connect the
connector.
Step
Check
Check of toner cartridge attachment
4
Re-attach the toner cartridge, and make a test
print of the problem image.
Is the image printed normally?
Check of 2ND BTR ASSY
5
Remove 2ND BTR ASSY.
Is 2ND BTR ASSY normal without any dirt,
damage or wear?
Check of contact between Photoconductor
6
Unit and frame
Are the contacts of Photoconductor Unit and
HOUSING ASSY-GUIDE AD dirty or
deformed?
Check after replacement of Photoconductor
7
Unit
Replace Photoconductor Unit.
Make a test print of the problem image.
Is the image printed normally?
Check after replacement of Toner Cartridge
8
Replace Toner Cartridge Y/M/C/K.
Make a test print of the problem image.
Is the image printed normally?
Check after replacement of PWBA MCU
9
Replace PWBA MCU.
Make a test print of the problem image.
Is the image printed normally?
Check after replacement of ROS ASSY
10
Replace ROS ASSY.
(p.401)
Make a test print of the problem image.
Is the image printed normally?
Check after replacement of MOT ASSY
11
MAG
Replace MOT ASSY MAG.
Make a test print of the problem image.
Is the image printed normally?
Printer
Yes
End of procedure Go to Step [5].
Go to Step [6].
(p.374)
Clean or replace
relevant parts.
End of procedure Go to Step [8].
End of procedure Go to step [9]
End of procedure Go to Step [10].
(p.432)
End of procedure Go to Step [11].
End of procedure Go to Step [12].
(p.423)
Revision B
No
Replace 2ND
BTR ASSY.
(p.374)
Go to Step [7].