20. Alerts; Introduction; Overview - Furuno FCR-2107 Series Operator's Manual

Marine radar/arpa
Hide thumbs Also See for FCR-2107 Series:
Table of Contents

Advertisement

20. Alerts

20.1

Introduction

FCR-2xx7 is designed to meet requirements set on paper "IMO MSC 252(83)" about use of alert concept instead of
alarm concept. Main purpose of this is to reduce continuous alarm bell ringing. In the new concept old alarms are
called as alerts and they are subdivided into 3 groups, out of which only alarm provide continuous alarm bell ringing
Alerts generated by Chart Radar are divided into three categories:
• Alarm, only the most urgent alerts which needs your immediate attention. Color of alarm is red and they flash
and beep until acknowledged.
Warning, most of alerts are in this category. Color of warning is yellow, in begin of warning there is a short
beep and they flash until acknowledged. If a warning is not acknowledged within 60 seconds then the short beep
is repeated.
Caution, color of caution is yellow and it is used to indicate doubtful condition.
20.2

Overview

Alerts are displayed on the ENC screen at the lower right corner, indicated with "1" in the figure below. "2" in the
figure below is the Alert Box, where you acknowledge alerts and display the Alert Queue window which shows
alerts generated. To acknowledge an alert or display the Alert Queue window put the cursor in the alert area then
push the left mouse button to acknowledge an alert or push the right mouse button to display the Alert Queue
window.
There are two kind of alerts generated by the ENC. To see a list of alerts, see section 20.10 List of Alerts.
20-1