7. Vector Chart Material
7.4.4
Viewing status and setting viewing dates of S57 chart cells and their
updates
When you load S57 chart cell(s) and/or their updates, the system sets Display Until of S57 chart cell(s) as current
date of the system. To set Approve Until as current date of the system, you must open the Set Chart viewing dates
dialog box and perform Approve Until. You can view status and set viewing dates of S57 chart cells and their
updates. To view status and date dependency, do the following:
RENC edt / upd: The column "RENC" contains edition/update status from Product List.
SENC edt / upd: The column "SENC" contain edition/update status from "SENC", i.e., loaded and converted in the
chart radar.
Updates displ. until: "date until updates" is displayed. You can enter desired date by using the Display Until field.
The number after the date shows the number of updates for the displayed cell (number of displayed updates /
number of updates in SENC format).
Updates approv. until: View the Date Until updates is approved. You can enter desired date by using the Approve
Until field (number of approved updates / number of updates in SENC format).
The issue date of the Product List used is displayed as "Latest RENC Product List". An RENC Product List contains
information about the charts stored in RENC and the date when the Product List was issued. If the chart radar does
not contain any Product List, then the date of the Product List is displayed as "—NVLD—".
The ">>>" mark is used to indicate that a chart is not up-to-date. The "<<<" mark is used to indicate that SENC
contains newer information than the information in an RENC Product List. (You can need to load newer RENC
Product List.) Cancelled charts are indicated as "cancelled" instead of "edtn/updn". If an SENC contains a cancelled
chart, then the indication ">>>" is replaced with "XXX".
7-34
1.
Choose Set Chart viewing dates from the Chart menu. The Chart Viewing
date dialog box appears.
Recommended settings in Chart viewing date are:
Sync Manual Update Dates: ON position
All SENCs: ON position

Hide quick links: