Installation Parameter For Wind Sensor - Furuno FCR-2107 Series Operator's Manual

Marine radar/arpa
Hide thumbs Also See for FCR-2107 Series:
Table of Contents

Advertisement

True wind or Relative wind may be selected from the Other dialog box in the Sensors menu.
POSN
kn
kn
15.8.1

Installation parameter for wind sensor

There are installation parameters for a wind sensor:
Source of True wind (Setting for inputted serial data)
Display format (Relative wind, true wind)
Output format to TT (output format to TT)
The tables which follow describe the above-mentioned parameters. Greyed options are default settings.
Source of true wind
Option
Receive (R)elative/Apparent Wind and Calculate True
Wind
Receive (T)heoretical Wind(HDG) and Calculate True
Wind
Receiver (T)rue Wind(North) and use it directly
Display format
Option
Display Rel(=Theoretical) or True(=North)
Display Rel(=Apparent) or True(=North)
Display Rel(=Apparent) or True(=Theoretical)
Relative wind/true wind
selection box
Description
R(Relative) is extracted from the MWV sentence, read
as Apparent data and North and Theoretical are
calculated.
T(True) is extracted from the MWV sentence, read as
Theoretical data and North and Apparent are calculated.
T(True) is extracted from the MWV sentence, read as
North data and Apparent and Theoretical are calculated.
Option in Sensor dialog box
Rel wind
Theoretical
Apparent
Apparent
15. Navigation Sensors
True wind
North
North
Theoretical
15-17

Hide quick links:

Advertisement

Table of Contents
loading