Figure 60: Installing a Line Card with a 2-in. Ejector Lever

Captive
screw
EX8 200- 40X S
Ejector
levers

Figure 61: Installing a Line Card with a 4-in. Ejector Lever

Tighten the captive screws on the faceplate of the line card by using the screwdriver.
9.
Verify that the
ON
LED starts blinking in green. When the
10.
card is ready for use. If the
"Troubleshooting Line Card Installation on EX8200 Switches" on page 237.
CAUTION: After the
before installing another line card or removing a line card.
You can verify that the line card is functioning correctly by issuing the
and
show chassis fpc pic-status
NOTE: If you have a Juniper J-Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/csc/management/updateinstallbase.jsp
Failure to do so can result in significant delays if you need replacement parts.
This note applies if you change the type of line card. It does not apply if you
replace these components with the same type of component.
Removing a Line Card from an EX8200 Switch on page 216
8-port SFP+ Line Card in an EX8200 Switch on page 32
40-port SFP+ Line Card in an EX8200 Switch on page 33
Chapter 9: Installing Switch Components
LED does not blink or is not lit steadily, see
ON
ON
LED is lit steadily, wait for at least 30 seconds
commands.
ON
LED is lit steadily, the line
show chassis fpc
.
157