Juniper EX8208 Complete Hardware Manual page 49

Juniper networks switch user manual
Hide thumbs Also See for EX8208:
Table of Contents

Advertisement

Table 8: LCD Panel Menu Options for the EX8200 Switch (continued)
Menu
Description
Maintenance
The Maintenance menu has the following options:
SYSTEM HALT?—Choose one of the following:
Press
Enter
EX8216 switch. Press
In a base configuration switch, the master SRE or RE module will be gracefully halted but not powered
off. Press
In a redundant configuration, the backup SRE or RE module takes over mastership when the master SRE
or RE module is halted. To completely halt the switch, use the
CLI command to halt the backup SRE or RE module before halting the master SRE or RE module. Press
on your management device or power cycle the switch to bring the switch back up.
Enter
See "EX8208 Switch Configurations" on page 7 or EX8216 Switch Configurations for information on
configuration types.
Press
Menu
SYSTEM REBOOT?—Choose one of the following:
Press
Enter
Press
Menu
LOAD RESCUE?—Choose one of the following:
Press
Enter
rollback.
Press
Menu
FACTORY DEFAULT?—Choose one of the following:
Press
Enter
restoration. The LCD flashes a success or failure message and returns to the Idle menu.
Press
Menu
ENTER EZSETUP?—Choose one of the following:
Press
Enter
EZSetup configures DHCP and enables the J-Web user interface on the switch. The LCD flashes a success
or failure message for approximately 10 seconds and returns to the Idle menu.
Press
Menu
NOTE: You can use the EZSetup option only if the switch is in the factory default configuration.
EXIT MAINT MENU?—Choose one of the following:
Press
Enter
Press
Menu
If you do not want users to use Maintenance menu options, disable the entire menu or individual menu options.
See Configuring the LCD Panel on EX Series Switches (CLI Procedure).
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
to halt the master SRE module in an EX8208 switch or to halt the master RE module in an
again to confirm the halt.
Enter
on your management device or power cycle the switch to bring the switch back up.
Enter
to go to the next option in the Maintenance menu.
to reboot the master SRE or RE module. Press
to go to the next option in the Maintenance menu.
to roll back the switch to the previous valid configuration. Press
to go to the next option in the Maintenance menu.
to restore the switch to the factory default configuration. Press
to go to the next option in the Maintenance menu.
to launch EZSetup. Press
to go to the next option in the Maintenance menu.
to exit the Maintenance menu.
to return to the SYSTEM HALT option.
You can view the information about the LCD panel in EX8200 switches by executing the
command
show chassis hardware
description of the LCD panel.
Chassis Status LEDs in an EX8200 Switch on page 24
Field-Replaceable Units in an EX8208 Switch on page 25
Field-Replaceable Units in an EX8216 Switch
request system halt other-routing-engine
again to confirm the reboot.
Enter
again to confirm the launch.
Enter
. It shows the version, part number, serial number, and
Chapter 2: Component Descriptions
again to confirm the
Enter
again to confirm the
Enter
23