Figure 87: Location Of The Esd Point On An Ex8200 Switch Chassis; Figure 88: Closed And Open Positions Of The 2-In. Ejector Lever - Juniper EX8208 Complete Hardware Manual

Juniper networks switch user manual
Hide thumbs Also See for EX8208:
Table of Contents

Advertisement

Copyright © 2010, Juniper Networks, Inc.
Ensure that you have the following parts and tools available to remove a line card from
an EX8200 switch chassis:
ESD grounding strap
Phillips (+) screwdriver, number 2
An antistatic bag or an antistatic mat
Replacement line card or a cover panel and its captive screws to cover the empty slot
To remove a line card from an EX8200 switch:
Place the antistatic bag or antistatic mat on a flat, stable surface.
1.
Attach the ESD grounding strap to your bare wrist and connect the strap to the ESD
2.
point on the switch chassis (see Figure 87 on page 217). The ESD point is at the same
location on EX8208 and EX8216 switches.

Figure 87: Location of the ESD Point on an EX8200 Switch Chassis

Label the cables connected to each port on the line card so you can reconnect the
3.
cables to the correct ports.
Take the line card offline by issuing the following CLI command:
4.
user@switch> request chassis fpc slot slot-number offline
Remove the captive screws on the faceplate of the line card by using the screwdriver.
5.
Grasp the ejector levers on the faceplate of the line card and pull them outward
6.
simultaneously until they are in the open position and the line card is fully unseated.
The closed and the open positions of the shorter ejector levers are not as markedly
distinguishable as those of the longer ones (see Figure 88 on page 217).

Figure 88: Closed and Open Positions of the 2-in. Ejector Lever

Closed
Line card
Ejector lever
Chapter 13: Removing Switch Components
Open
217