Option 51: 24 Hour Sensor Tamper; Option 52: Unvacated Premises; Option 53: Hardwire Siren Supervision; Option 54: Access Code Length - GE Euro Simon Installation Instructions Manual

Table of Contents

Advertisement

Note
This feature does not work
from a keychain touchpad.
Note
Option 38: Auto Arm must
be on for this feature to
work.
29
Delete—Option #—50—DONE.
Option 51: 24 Hour Sensor Tamper (Default = off)
Determines whether the system (armed or disarmed) goes into and reports an alarm anytime a
sensor tamper switch is tripped (on), or only when the system is armed and a tamper switch of
an armed sensor is tripped (off).
¾
To turn on 24 Hour Tamper, press:
Add—Option #—51—DONE.
¾
To turn off 24 Hour Tamper, press:
Delete—Option #—51—DONE.
Option 52: Unvacated Premises (Default = off)
Determines whether the system automatically arms down to level 2 (ARM Doors & Windows)
if the user arms the system to level 4 (ARM Doors & Windows + ARM Motion Sensors) with-
out leaving the premises (on), or remains at the armed level chosen by the user (off).
If this option is turned on and the user arms to level 4 (ARM Doors & Windows, + ARM
Motion Sensors) but does not exit the premises within the Exit Delay time, the panel automati-
cally changes to arming level 2.
¾
To turn on Unvacated Premises, press:
Add—Option #—52—DONE.
¾
To turn off Unvacated Premises, press:
Delete—Option #—52—DONE.
Option 53: Hardwire Siren Supervision (Default = off)
Determines whether the panel monitors hardwired sirens for open conditions (on), or not (off).
If this option is turned on, sirens connected to the panel terminals require an EOL resistor in
the wire circuit (see "Installing the System" for siren supervision wiring). If this option is
turned off, EOL resistors are not required whether sirens are connected or not.
¾
To turn on Hardwire Siren Supervision, press:
Add—Option #—53—DONE.
¾
To turn off Hardwire Siren Supervision, press:
Delete—Option #—53—DONE.
Option 54: Access Code Length (Default = 4)
Determines how many digits are in all access codes.
Turning on this option lets you set the access code length to 3, 4, 5, or 6 digits. Turning off this
option resets the access code length to the default setting, resets Master, Utility 1, and Utility
access codes.
Read the following before changing this option.
This option affects all system access codes (Master, Utility 1, Utility 2, Panic, and User).
Changing the access code length changes the Master, Utility 1, and Utility 2 access codes
to their respective defaults as described in the following table.
Note
Changing the Access Code Length clears/deletes any User Codes that were previously programmed.
If the customer wants the Access Code Length changed, it should be set before programming any