Base Sensor Test

The Base Sensor Test is used to determine that the sensors located inside the printer are
operating correctly. The following sensors can be checked using this test:
To run the Base Printer Sensor Test.
1.
2.

5-Bin Mailbox Diverter Test

Note: This test checks the operation of each mailbox output diverter. Also if more than
one 5-Bin mailbox option is installed, the test checks all of the diverters installed on the
printer.
When the test is selected from the diagnostic menu the following is displayed:
This is a single test. The test terminates upon completion.
5060-XXX
<output bin> (output bin displayed on line 1 = output bin 1, output bin2, output
bin3, output bin4 or output bin 5 for the bin selector)
P1 = 5-Bin mailbox first pass thru sensor
P2 = 5-Bin mailbox second pass thru sensor
L = EM 5-Bin x empty
L = NL bin contains media but the bin is not near full or full
L = NF bin is near full
L = FL bin is full
* Input Sensor S1
* Input Sensor S2
* Inline Media Sensor
* Fuser Exit Sensor
Select Base Printer Sensor Test from the menu.
The operator panel displays OP for open and CL for closed.
Manually toggle the sensors by hand to verify that each sensor switches from open
to closed.