Step
Action and Questions
9
Check to make sure that the Pass Thru Sensor is correctly
connected to the Tray X system board.
Is the sensor cable connected correctly?
10
Check the Autocompensator cable for correct installation to
Tray x System board.
Is the cable connected correctly?
11
Check the base door assembly, paper guide, wall support
plate and door spring for any signs of damaged parts,
warped parts or obstructions that might cause the paper to
jam over the pass thru sensor.
Did you find any problems with these parts?
The printer does not detect transparencies loaded in Tray x.
Step
Action and Questions
1
Check the transparency material to make sure it meets
specifications.
Does the transparency material meet specifications?
2
Check the Transparency Sensing Assembly for correct
installation.
Is the Transparency Sensing Assembly correctly installed?
3
Check the Transparency Sensing Assembly cable to make
sure the in-line connector is correctly installed to Tray x
System board cable.
Is the cable correctly installed?
4
Check the Transparency Sensing Assembly cable to correct
installation to Tray x System board.
Is the cable connected correctly?
2-114
Service Manual
5060-XXX
Yes
Replace the
FRU's in the
following order:
1. Pass Thru
2. Electronics/
Go to step 11
Repair or
replace parts
as necessary
Yes
Go to step 2
Go to step 3
Go to step 4
Replace the
FRU's in the
following order:
1. Transparency
2. Electronics/
No
Install the
cable correctly
Sensor
Assembly
Size Sensing
Assembly
Install the
cable correctly
Replace the
Autocompen-
sator
Assembly
No
Inform the
customer that
the
transparency
media in tray x
does not meet
specification
Install the
Transparency
Assembly
correctly
Install the
cable correctly
Install the
cable correctly
Sensor
Assembly
Size Sensing
Assembly