User Primary
Message
36 Printer Service
Required
37 Insufficient
Collation Area
5060-XXX
User Secondary Message
Explanation
This message will be displayed when background
toner has prevented a completion of a TPS
calibration cycle. Service will be required to fix
the problem.
The following action can be taken while this
message is displayed:
* Press Go to clear the error.
The following Warning message may be
displayed:
Service Printer
This Warning message means that a TPS failure
has most likely occurred. The printer will continue
to operate but the color quality will most likely be
degraded. The most probable cause for this error
message is a defective print cartridge or ITU.
This message will be displayed when the printer
memory and disk used to store pages is too full to
collate the print job.
The following actions can be taken while this
message is displayed:
* Press Go to clear the message and continue
collating the remaining pages of the job
or
* Press Menu> or Menu< to access the Busy/
Waiting Menu Group.
The following functions will be available via the
Busy/Waiting Menu.
* Cancel Job
* Reset Printer
* Reset Active Bin
* Check Supply Levels
Note: Menu Lockout does NOT prevent access to
the Busy/Waiting Menu Group.