Strip Sensitivity Setting ([Peel]); Detals Of Sensor Adjustment Value Display (Sensor A/D Value Display) - Toshiba B-EP2DL Series System Mode Manual

Hide thumbs Also See for B-EP2DL Series:
Table of Contents

Advertisement

4. SYSTEM MODE (For Service Persons and System Administrators)

4.7.2 Strip Sensitivity Setting ([PEEL])

This setting is used for sensitivity adjustment of strip sensor.
[FEED]
[PAUSE]
Notes:
1.
When the [FEED] key is pressed, the menu moves in the opposite direction from when the [PAUSE]
key is pressed.
2.
When the [FEED] and [PAUSE] keys are simultaneously pressed, the display returns to the system
mode menu.
3.
When the [FEED] key or [PAUSE] key is pressed for 0.5 seconds or more during this setting, repeat
mode is enabled and the key pressed is repeatedly entered.

4.7.3 Detals of Sensor adjustment Value Display (Sensor A/D Value Display)

(1) Thermal Head Thermistor and Ambient Thermistor Status
H:20°C
(2) Reflective (Black Mark) Sensor Status
[REFLECT]
(3) Transmissive (Feed Gap) Sensor Status
[TRANS.]
(4) Reflective Sensor and Transmissive Sensor Status (without paper)
[PE]R4.6V
[PEEL.]
AUTO
[PEEL.]
1
[PEEL.]
2
A:+22°C
Ambient thermistor status
15 °C to 86°C
Thermal head thermistor status
15 °C to 86°C
3.8V
Reflective sensor status
0.0V to 5.0V
2.3V
Transmissive sensor status
0.0V to 5.0V
T4.3V
Transmissive sensor level without paper
0.0V to 5.0V
Transmissive sensor level without paper
0.0V to 5.0V
Automatic sensitivity adjustment (Factory default)
Low sensitivity
High sensitivity
4- 65
EO13-33005
4.7 Sensor Display/Adjustment

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-ep4dl series

Table of Contents