Poor Color Registration - Toshiba e-STUDIO 20CP Service Manual

Table of Contents

Advertisement

Step A
Step
Action and Questions
1
Print Cartridge - Check to make sure the print cartridge is
seated correctly.
Is the Print Cartridge seated correctly?
2
The print cartridge may be out of toner. Try a new print
cartridge.
Does a new print cartridge fix the problem?
Step B
Step
Action and Questions
1
Check to make sure that Color Calibration has not been
disabled in the CE menus, especially if the printer has been
previously serviced.
Was Color Calibration disabled?
2
Toner Density Calibration - Run Toner Density Calibration
from the Utility menu.
Does this fix the problem?

Poor Color Registration

Step
Action and Questions
1
Print Cartridge - Check to make sure that the print
cartridges are properly inserted and are seated properly in
there respective V Blocks.
Are the cartridges seated correctly?
2
Front Cover - Check the front cover to make sure that all the
springs and cartridge hold downs are present and correctly
installed.
Are all springs and cartridge hold downs present and
correctly installed?
5060-XXX
Yes
No
Go to Step 2
Install the
print cartridge
correctly and
recheck.
Problem
Replace the
Solved
"HVPS
Transfer
Board" on
page 4-12
Yes
No
Set Color
Go to step 2
Calibration on
Problem
Replace the
Solved
"HVPS
Transfer
Board" on
page 4-12
Yes
No
Go to Step 2
Install the
cartridge(s)
correctly.
Go to Step 3
Replace any
missing or
damaged
springs.
Replace any
missing or
broken hold
downs.
Diagnostic Information
2-75

Advertisement

Table of Contents
loading